ao smith water heater error code e05

FIX: Check for blockage in the vents, the distance between the intake and exhaust terminals are per instructions and remove if there is grease or dirt in the gas burner and fan motor. All rights reservedDisclaimer:The content published on hotwatertalk.com is not professional advice. Either the thermopile doesnt cool down quickly or the pilot valve is stuck in an open position. Blue light now heartbeat dim & bright. Instruction Manual - High quality water heaters and water treatment . Here are The Facts! And like other electric water heaters, AO Smith also features a high-limit switch or electric-cut-off button. Turn the gas supply on and check for leaks by spraying soap solution on the connections. It is a 50 gallon A O Smith just installed in new home 6 months ago.LG12-50R55DV 210. Smith Water Heater, look no further! Solution: Check if the condensate drain is installed on the vent collar of the heater. This morning it started beeping again but still no error message. Problem: Problem with the computer board. Pentair heater error codes are ERR PS, ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, and E06. This cookie is set by GDPR Cookie Consent plugin. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet. CODE: 03 (031), One timePROBLEM: Incorrect dipswitch settings. Is Spray Paint Flammable? Otherwise, the status light wont blink. In other words, the thermopile itself gets defective or the wire connectors come loose. Models from the 240, 340, and 540 series will show the error codes on both temperature controller and remote controller. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! The consent submitted will only be used for data processing originating from this website. But if you have to increase the water temperature, try to stay well below 150F (65C) so the high limit switch doesn't trip. Open the control panel and make sure that the stack flue sensor is working properly. In one of the other places I manage, the owner -- for reasons known best to herself -- had a State Electric Hybrid water heater installed. Sometimes if you are lucky, it could just be a bit of soot blocking the sensors other times, you may need to find a replacement AFR rod as soon as possible. The initial setting is 120F, but you're in control after installation. Turn the gas control valve to the off position in the first place. A.O. If there is a scale build up, then you should also check for any water leakages that are causing scale to build up inside your water heater. Then, watch this tutorial and follow the steps to get the temperature sensor replaced: If you observe the status light of your water heater flashes 7 times consecutively with a three-second pause, understand the gas valve is at fault. If you have either a 2-chamber or 4-chamber model of AO Smith Water Heater, you can see the trouble codes E20, E21, E22, E23, and E24 for a single reason. You should keep depressing the igniter button for 90 seconds. CODE: 711, One timePROBLEM: Gas solenoid valve drive circuit failure. Find the right water treatment products for your needs. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Jenn-Air JGS8750ADB Control Panel Burning Hot! event : evt, Now, set the gas control knob to the Pilot position. To fix this issue, you should replace the control board. The leak of carbon monoxide is one of the carbon monoxide poisoning causes. The board replacement kit includes replacement yellow and blue wires with new connectors. Though the brand is different, it will help you a lot in finding the leaking point. Fixing the error as soon as it appears is important for the performance and longevity of the pool heater. AO Smith Water Heater Error Code E02 [5 Easy Fixes] 1. callback: cb You can easily detect the exact problem of your water heater if you know the meaning of the flashing light code. As a result, the heating element stops warming the water. However, we often suggest professional help if the issue is complex. AO Smith electric water heater keeps shutting off, e02 mike4500 Jun 18, 2019 M mike4500 Premium Member Joined Jun 18, 2019 Messages 5 Location NJ Jun 18, 2019 #1 Model Number 50 g Brand -brand- Age 1-5 years I have an AO Smith 50 gallon with the electronic display. Related Troubleshooting Pages:A.O. FIX: Is the water heater set for the right elevation? I hav been reading some similar posts regarding this issue, and I think I have made the proper analysis. They also have to make sure that the flame rod does not come with soot. })(); Anthony Barnes is the founder of Water Heater Hub and a second-generation plumber by profession. Smith Water Heater error code guide will explain common issues, provide tips, and show you how to read your model's error codes. Now, relight the pilot light by following the step-by-step guide I mentioned earlier in this article. If there is air in the waterline, your water heater may throw this erratic code. Learn more, Facebook II Twitter II Pinterest II Linkedin. If you own an AO Smith tankless water heater, then its important that you know how it works and what to do when things go wrong. This error code occurs when there is a problem with the inlet thermistor. Release the gas control knob once the status light starts flashing and set the temperature to your desired setting. Fortunately, I broke down every common error code your AO Smith Electric Water Heater shows. (function() { This error code may appear when you power up the unit. advanced settings. Smith University | An Education in Hotwater Register NOW for live online workshops! Then, use a flathead screwdriver to remove the nuts that hold the upper access panel in its place. And the reason is the thermistor gets shorted electrically. So, whenever the error code pops up on the heater display, fix it with the help of our guide by yourself. Make sure that you maintain a cleaning schedule to keep the pipes clear and functional. In the Pentair pool heater exchanger, the thermal regulator helps the water reach a certain temperature and heat up the pool water. If it's shorted out, unplug the machine . Premium 5500 Watt Stainless Steel Heating Elements are more efficient and longer lasting than conventional elements, with higher recovery. For example, a model 510 will display the numerical code on the 7-Seg LED on the computer board, while the 110 and 310 models only a blinking red LED that can flash one time or more. We hope that this article has provided you with some useful information about AO Smith tankless errors codes. As long as you see this error code, you must turn off the water heater first. Model HPX-66-DHPT120. Smith Water Heater Age Determination - reader comment: (May 11, 2012) AO Smith employee said: To tell the age of any AO Smith water is the first 4 numbers. Tank Guard gives you advanced tank protectionextends the life of your water heater. We and our partners use cookies to Store and/or access information on a device. Once I did that and cleaned out the sediment, I had an e02 error code on the panel. Water Heaters - A.O. You may need to install Adobe Acrobat Reader to view these documents. If you own a 540 model AO Smith tankless water heater, then this is an error code that may appear on your display screen. {{INUSING}}, Water Heater Expansion Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. How To Fix: First off, turn the gas control knob to the off position. Smith Signature 100 50-Gallons Tall 6-year Limited Warranty 4500-Watt Double Element Electric Water Heater Model # E6-50H45DV Find My Store for pricing and availability 2930 A.O. People only need to check for the right setting on the computer board of the water heater. The solution for this problem is by checking the Hi-limit switch. Just connect a garden hose to the drain plug at the bottom of the unit and place the other end of the hose to the nearest floor drain. Press down the gas control knob all the way in while depressing the igniter button continuously. To solve this error, you will need to carry out the same checks and treatments in the above error. So, keep reading. Join our exclusive 2,500+ email list to get tailored advice, product roundups, and be the first to see our new content. Yesterday morning my water heater was beeping but no error code. Double check with your water heaters manual first and if everything seems to be fine, then you need to call out a technician. I don't think I should have yo pay anyone. Smith - Troubleshooting help - Hello my frist post here. The Solution Connections: Make sure the wiring is connected properly and isn't damaged. Changing the gas control valve is not as difficult as you assume. When the heating element shorts out, it will cause a short circuit, which will allow it to continue heating, causing the water to become too hot. Scale build up could be the cause of locking the motor drive and is usually caused by a water leak somewhere within your water heater. Solution: Check for connection and wire breakage or computer board failure (burn marks). BFC Cyclone Twister II Related Parts Pages:A.O. Hi, I have an AO Smith GCVL 40 300 natural gas with a Honeywell valve. {{INUSING}}, The average cost per Gallon is ${{PROPANEGASPRICE}} This error code signifies that there is a problem with your outlet thermistor. Solution: Debris on the thermistor, loose or broken wire connection. This applies both to the choice of materials and components used in the manufacturing process, as well as to the efficiency of the finished products. Check if there are any foreign particles or grease on the gas burner and fan motor. Smith A.O. Resetting your water heater is a simple fix to this problem and helps you clear the error message. So Scale is caused by water settling on heat transfer surfaces and the impurities build up into a hard, crusty layer. Alternatively, it could be that debris has affected the flow sensors impeller and just needs a bit of cleaning to get back to functioning as normal. Leak Watch Smart technologyimmediately alerts you of a leak for yourpeace of mind. Here, we will explore and discuss each and every reason that results in the E05 Pentair heater error. Thirdly, locate the thermistor on your water heater. Nevertheless, it will mean that people have to learn more about Ao Smith Water Heater Codes for understanding the error and the solution. Thank you. You also have the option to opt-out of these cookies. When it senses the water temperature crosses the safety level, the reset or ECO button cuts the electric supply off. There are a range of potential causes to this error. Examine the water pipes and make sure that they are clean. http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intellivent, When Used On Gas, Residential, Power Vented. A Pentair pool heater typically functions for 6 to 12 years on average. The industry's first peace of mind, scale inclusive, 15-year warranty. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. The cookie is used to store the user consent for the cookies in the category "Other. An Easy Guide on How to Fix A Squeaky Door Without Taking It Apart, How to Remove A Broken Drill Bit from Wood? Some people think that a tankless water heater will be a great choice. Explore symptoms, causes, and a step-by-step repair guide for an easy repair. Clean away any dirt or debris and check the quality of the connection wires. An example of data being processed may be a unique identifier stored in a cookie. If you're looking for help fixing your A.O. The gas pressure to the Pentair pool heater often gets obstructed due to clogged gas pipes, incorrect pressure settings, and turned off gas valves. ao smith water heater error code e05. CODE: 74, 741, 751PROBLEM: Miscommunication between the water heater and remote controller. The tools needed to solve the problems from below are mainly the screwdriver, manometer, and multi-meter. The accumulated water will not allow the Pentair pool heater to work properly or shut off completely. How to troubleshoot Rinnai water heaters successfully using Rinnai error codes guide. The flame rod should be free from dirt and grease, and the computer board should not be damaged. To fix the tankless water heater from AO Smith properly and fast, we will show all three error codes (in the subtitle), the first for the units with the remote controller, the second for the units with the 7-Seg LED, and third are those heaters that do not have the remote only blinking LED. Use the AO Smith code guide to find the main causes and solutions for the problems of the following models: 110, 310, 510, 240, 340, and 540 series, for safety, convenience, and great savings. All of the above error codes all point to the same problem: an issue with your gas solenoid valve. Look for the blockage in the vent system and ensure if the distance between the intake and exhaust is not too small. FIX: Check the wire connection, wire breakage and debris on the flow sensor impeller. All Right Reserved by FIREPLACEHUBS. Solution: See the error codes 331, 321, and 311. For example, a bad thermostat, a bad computer board, and burn-out connectors that lead to the computer module are responsible for producing too much hot water. The LED status light flashes 0 times or it doesnt come on due to two reasons. In a 6-flat/3 story building with 6 apartments/total of 15-16 residents, I have an AO Smith water heater/25 yrs old with specifications of 81 gall capacity, 149 gall/hr recovery, 154,000 BTU. Of course, you are always open to reaching out to a professional if you fail to clear the error messages. For example, if the status light blinks 2 times, there is an issue with the thermopile voltage output. Before you start to disassemble your water heater, remember to shut off its power and that you reassemble it correctly. If this doesnt bring any luck to you, the best bait is to call a professional for further assistance. Turn the gas control knob to the off position by moving it counter-clockwise. However, a damaged thermal regulator often prevents the water from flowing out, causing it to be trapped in the exchanger. FIX: See error codes 111 and 121. c. The computer checks for any problems with the unit before startup. It also causes the heater to shut down completely and display the E05 code on the Pentair heater. FIX: Check if the condensate drain is installed on the vent collar of the heater. If everything seems to be in order but your water heater is still failing to ignite, then it is safer to call out a technician to take a look at it. Conduct checks on all the parts and sensors on a regular basis. A.o. If the status light still doesnt come on, I bet the pilot flame fails to heat the thermopile sufficiently. smith gas water heater installation user and service manual (102 pages) Water Heater A.O.Smith GPSX-50L Owner's Manual. Our comprehensive A.O. This problem occurs because of two reasons. Generally, the water heater will display this faulty code if the outlet thermistor (TH-4) remains open. They have to make sure that it can function properly. ST. Manual for 300 models. This chapter will describe the meaning of a specific error message your AO Smith Electric Tankless Water Heater throws. Next, use the -inch open-end wrench and pull out the thermistor by turning it counter-clockwise. I replaced the upper element, and then replaced the thermostat as tech support said that might be causing the problem. Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. This is the error code for ignition failure. However, I highly recommend you call a certified plumber to solve this issue. This cookie is set by GDPR Cookie Consent plugin. 7+ Common AO Smith Water Heater Troubleshooting Codes. Anyway, whats the last time you flush your AO Smith Water Heater? Solution: Check if the remote controller is of the right type, also connections between the water heater and remote. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. What you need to do is- attach the thermistor wires to the control board. Copyright 2020 - 2022 | All rights reserved. ); People can find those advantages from AO Smith tankless water heater. Turn the electric power to your water heater off at the circuit breaker. Solution: Check for the proper settings on the computer board. A list of Takagi error codes for easy troubleshooting of Takagi tankless water heaters. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. A.O. A faulty code E06 on your AO Smith Water Heater stands for too hot water temperature. There will be various considerations which should be made in this circumstance for finding the perfect one. Understanding Noritz error codes and troubleshooting Noritz water heaters. Solution: Is the water heater set for the right elevation? Launch Product Selector. It may take 90 seconds of pilot operation before the thermopile comes to its normal operating temp. A.O. We will also tell you the solutions that will help you to fix the problem. Your AO Smith Electric Water Heater will throw the error codes E10, E11, E12, and E13 either for an open inlet temperature sensor or open thermistor. CODE: 11 (111), Three timesPROBLEM: The ignition failure. As a result, you can now easily diagnose your water heater that will save you both time and money. Can you hear a buzzing spark ignition from the burner or two clunk sounds from the gas valve? To solve this, you will need to unblock your vents and also check for any grease or dirt found within the gas burner or fan motor. Like other heat pump water heaters, AO Smith Heat Pump Water Heater uses the ECC or transformative solid state technology to reduce the energy usage. This time, it is referring to a problem with your exhaust thermistor. So not happy that I had to replace it, but very happy with AO Smith that they honored the warranty. View more. No, it's not. Comprehensive information about your new appliance - from getting started to cleaning and maintenance - with answers to frequently asked questions. Not only that, but it also causes the Pentair pool heater to turn off. Analytical cookies are used to understand how visitors interact with the website. Fix or replace the faulty parts, wires, or pipes as soon as you notice them. Smith Signature 100 50-Gallons Tall 6-year Limited 40000-BTU Natural Gas Water Heater Model # G6N-T5040NVR If there is no scale, then you should also check the connections and wires for damage or looseness. Copyright. Afterward, put everything back into its place. Read also : Noritz Error Code Troubleshooting. Smith Water Heater Prices. Get information and support for all A. O. Smith models. Then, ensure you have the following pieces of equipment at your fingertips: Secondly, check the user manual and drain the water heater by following the instructions. The fan motor could also be blocked by dust, debris or dirt and needs a clean. This chapter will discuss everything you need to know about the flashing light codes on AO Smith Water Heater. The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Clean the sensor along with the terminals and put it back in place. More error codes can be found after all. You can hear the buzzing of the spark igniter. Solution: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. A thin or low flow of water to or from the water heater can also cause the e05 on Pentair heater display. Put everything back into its place and turn the electricity on. Possibly a short somewhere, check all your wires for frayed or cut insulation on them shorting out. Why is my AO Smith water heater not lighting? Products. The solution to this problem is just the same as the previous error code check for broken wires, damage, loose connections, dirt and debris. Check the gas valve and make sure that it is turned on completely. A guide to troubleshooting water heaters with the listed error codes below is useful for DIY homeowners, but our recommendation is always to get help from a qualified technician. When the temperature of the stack flue rises above a certain degree, this error message will show up on your heater. They have to make sure that it can function properly. Low water flow and loose wiring also contribute to the Pentair Mastertemp e05 code. Smith NG water heater Commercial Shut down.

Nub Theory Wrong For Anyone, Que Significa Sentir Olor A Excremento De Perro, Pirates City Connect Jersey, Articles A

ao smith water heater error code e05